Solved: Hello I want to configure 2 different RAIDs on a DL G5 with a P RAID controller. I want Disks 1 and 2 as a RAID1 and Disks 3, 4, 5 and 6 as a RAID I need to understand how to configure RAID Configuration on these servers. Last Night I have been provided a Remote Console access to this server through ILO. My task was to build this server with windows server R2 OS. The server has 5 HD in it each with 80 GB Capacity. I went to configure the RAID on the server by pressing F8.

Experts Exchange always has the answer, or at the least points me in the correct direction! It is like having another employee that is extremely experienced. Being involved with EE helped me to grow personally and professionally.

Connect with Certified Experts to gain insight and support on specific technology challenges including:. We've partnered with two important charities to provide clean water and computer science education to proliaht who need it most.

Get Access. Log In. Web Dev. We help IT Professionals succeed at work. Prashant Girennavar asked. Last Modified: How to configure raid on hp proliant dl380 g5 Experts, I am new to HP servers.

My task was to build this server with windows server R2 OS. Comment Premium Content You need a subscription to comment. Start Free Trial. Watch Question Premium Content You need a subscription to watch. What is the best karaoke hosting software Expert This award recognizes someone who has achieved high tech and professional accomplishments as an raif in a specific topic.

Commented: This problem has been solved! Why Experts Exchange? Jim Murphy. When asked, what has been your best career decision? Deciding to stick with EE. Mohamed Asif. Carl Webster. Experts Exchange Take hold of your future. All rights reserved. Covered by US Patent. Privacy Policy Terms of Use.

Post navigation

May 15, How to boot to RAID setup configuration utility on DL G6 and G7 I know on a G5 it would let you press F8 after it the RAID controller started but on a G6 and G7 I do not see that option. I need to be able to avoid using the HP SmartStart CD for engineers in the field. Mar 05, Easiest and safest way. Assuming your old raid array data can fit on an IDE or SATA drive.. Add a SATA or IDE drive to a SATA/IDE interface, clone the old array to the SATA or IDE drive; boot via the SATA or IDE drive. Shutdown, remove the old array, add the new drives, create new array. Boot to Windows,reverse clone from the SATA/IDE clone to the new array, telling cloning software to . You do not need to have any special CD to configure the RAID settings. RAID configuration tool is already built in the server. During the boot process, you need to enter the Intelligent Provisioning tool by pressing F Select Intelligent Provisioning and press enter. Then you need to select Smart Array Par controller as shown below: Click on Configure as below: Click on Create .

Log In. Chernobyl disaster.. Light travels faster than sound. That's why some people appear bright until you hear them speak. Thank you for helping keep Tek-Tips Forums free from inappropriate posts. The Tek-Tips staff will check this out and take appropriate action. Click Here to join Tek-Tips and talk with other members!

Already a Member? Join your peers on the Internet's largest technical computer professional community. It's easy to join and it's free. Register now while it's still free! Already a member? Close this window and log in. Join Us Close. Join Tek-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Students Click Here. I need to remove 4 old drives and replace it with 6 drives. How to i do this and configure RAID 5. How many spares drives do i need. I have never done this before. OS is Windows Server and is already installed. I wont be replacing hard drives where OS is installed. Please i need your urgent help on this task. Easiest and safest way Shutdown, remove the old array, add the new drives, create new array. Used Acronis and Paragon to do this. This could be done from an image also.

There is a way by replacing the present drives in the array with the larger new drives, then adding 2 more drives to expand the array, but far more work and not nearly as safe. Some stupid questions: 1. Copy data from existing RAID partition.

Shutdown server, remove old drives and add new 6 drives. Any additional hardware required? I need to 2 partitions, so i do i setup RAID for this.

The 3rd needs to be a spare? Here are some links to replacing the drives; the other option that technome mentioned. Thanks for the links. I dont want to extend. Just replace with bigger and more drives. I really don't want to answer without knowing for sure what you're environment looks like and you've already done; what step are you at?

Plus you're using technome's process, which is not how I've done it in the past. You want to replace the 4 data drives with 6 larger ones and configure them in a RAID5 with a hot spare? What RAID levels are your current drives? Do you have a backup of your current data drives that you have verified as containing everything you need to restore or the mirror configuration set up as described by technome?

When you get to the point of configuring the new array, I would shut down, replace the current 4 data drives with the 6 new ones and then boot from the smartstart CD and configure the new array. Hopefully technome can give you more detailed steps. Data on 4 drives RAID 5. I need to repaced the 4 drives with 6 larger drives. OS must stay intact. I will either use backup or copy to external drive to recover data.

Isn't the smartstart CD for loading the OS? My knowledge on RAID is entry level. Don't assume it's valid, confirm it. Then put the SmartStart CD into the drive cancel anything that autoruns power the server donw, replace the 4 data drives with the 6 new ones.

Boot the server from the smartstart CD. This is from memory so it may not be completely accurate Go into maintain server and then the array configuration utility ACU. Create an array and two logical volumes from the new drives. You should be able to get away with only needing 1 physical drive for a hot spare.

Then copy your data back onto the new drives. The way I described is used for the OS or block specific programs such as databases were a sector by sector copy is needed. Your raid 5 should be real simple and safe as Blister describes, simple copy data to another storage area, create new raid and copy back to new array unless you have a program such as SQL on the raid 5 ;as to NTFS security, you might want to use robocopy to copy data to maintain security permissions.

Agree, one hotspare will do, you might consider making the hotspare global to both arrays. Dont i have to delete the old array or logical drive first from ACU first?

Again, I normally don't do it this way. I do the replace-one-drive-at-a-time method. Then expand the array and either extend the logical drive or create another logical drive, when all the drives have been replaced. Seeing as you have already confirmed you have a good backup by this time and the OS is on another set of drives, at this point it would be easiest to delete the logical drive and array and completely recreate it. Expansion and extension take more time than just recreating it all.

However, be very sure you're dealing with the correct array before doing anything. I usually like to go wireless with my laptop and sit in front of the server. When you select drives they should light up to confirm you are dealing with the correct ones.

Good Luck. Red Flag This Post Please let us know here why this post is inappropriate. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. Close Box. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.

RE: How to build Raid 5 on DL G5 I really don't want to answer without knowing for sure what you're environment looks like and you've already done; what step are you at?

4 thoughts on “How to configure raid on hp proliant dl380 g5

  1. Vilar

    An immortal myth never claimed to be repeated.

    Reply

Add a comment